netBooter™NP-0801DUE (NEMA5-15 type outlet) and NP-0801DUEH (C13 type outlet) PDUs provide secured remote power source management of 8 independent outlets. Measures True RMS Current, Voltage, Active Power, Apparent Power, AC Frequency, Phase Factor, KWH and environment temperature monitoring* via TCP/IP networks or local direct connection.

Looking for additional networking features (SSH/LDAP/Radius/Syslog/Custom SSL) or billing grade energy (kWh) measurements with higher power capacity? Check Out SynLink Switched SP-1001B

Features:

  • 8 Independently managed power outlets.
  • Status LEDs for each outlet, link LED and device power LED
  • Configure and control with HTTP/HTTPS web interface or command line via Telnet / Serial
  • Measures True RMS Voltage, Current, Active Power, Apparent Power, AC Frequency, Phase Factor and KWH.
  • Supports TLSv1.2 encryption for HTTPS access
  • Source IP Address Access Filtering/Blocking
  • Use Autoping to reboot outlets after specified ping losses.
  • Daily reboot or weekly schedule for outlet on/off time.
  • Sync to NTP server or use real-time clock.
  • Sends event notifications via email or view local event log.
  • Restrict users to individual outlets as desired.
  • Use external dial-up modem for backend solution (DB9 serial port)

  • 8 x NEMA 5-15R Outlets - NP-0801DUE model

  • 8 x IEC 320 C13 Outlets - NP-0801DUEH model
  • Handles up to 15A at 110VAC - 10A at 230VAC
  • 1U enclosure: L 19" x W 6" x H 1.75"
  • 1 x DB9 RS232 Port: Data: 7 or 8 bits. Stop Bits: 1 or 2. Parity: None Flow Control: None. Baud Rate: 2400 to 115200.
  • Network Protocols: HTTP/HTTPS, IP/TCP, ICMP, NTP, SMTP, POP3, DHCP, Telnet, and BootP
  • Network Interface: 10/100-Base T. RJ-45.
  • Operational Temperature Environment: -25C° → 50C°
  • Humidity: 5-95%, non-condensing
  • Safety and Compliance: cTUV(US & Canada), UL-60950, FCC Class B

Specifications

Item NP-0801DUE / NP-0801DUEH
Dimensions 19” X 6.25” X 1.75” 1U
Input Power Voltage 110 VAC, 100VAC - 230VAC (H model)
Total Load
15A
Power Input 1 - IEC 320 C14 (Inlet)
AC Outlet Type 8 - NEMA 5-15R (Outlet) / 8 - IEC 320 -C13 (H model)
AC Energy
Monitoring
1 - Input Energy Sensor
Console Interface 1 - Serial Port. Data: 7 or 8 bits. Stop Bits: 1 or 2. Parity: None Flow Control: None. Baud Rate: 2400 to 115200.
Network Interface 10/100-Base T. RJ-45
Network Protocals ICMP, IP/TCP, NTP, SNMP, SMTP, DHCP, Telnet, HTTPS/HTTP and BootP
LED Indicators 8 - Power outlet On/Off status LEDs
1 - Network LED
1 - Device Power LED
Weight 8 Lbs
Operational Temperature -25C° – 50C°
Humidity 5-95%, non-condensing
UL/FCC Compliance TUV(US), UL-60950, FCC Class B