Remote Power and
Console Management
Phone: (760) 930-0473
Toll-Free: (866) 790-3897
Fax: (760) 930-0550

View Cart

Product Comparison Chart
NP netBooter
NP-02
    NP-02H
sidekick RPB-05
NP-0201D
NP-16
    NP-1601DH
    NP-16A30
    NP-16A20
    NP-1601D
NP-08
    NP-08G2
    NP-0801D
    NP0801DH
NPB-20
    NPB-20A30
    NPB-20A20
NPC netCommander
NC netConsole
AC Power Cords
Accessories


Back to Overview
NP-16
    NP-1601DH
    NP-16A30
    NP-16A20
    NP-1601D
2-U, 16 Port Remote Power Switch System
Overview


Click on image to view more
Overview
Highlights
Features
Specifications
Datasheet/Manuals
Demo

netBooter™ NP-16 provides secured remote power source management operation and AC current monitoring (optional) via TCP/IP networks or local direct connection. Accessing the system is password protected at Administration level or user privilege levels. Network security includes user name and password (64-bit encrypted) authentication for Web access or sending emails. NP-16 offers the most versatile access control methods in the industry for easy, quick and reliable operations.

NP-1601D is integrated with AC current monitoring module.
NP-1601DH is equipped with IEC-320 C13 outlets and IEC-320 C14 inlets. 220VAC power supply.
NP-16A20 is equipped with one input AC power cord with NEMA L5-20P plug.
NP-16A30 is installed with one input AC power cord with NEMA L5-30P plug.
Both NP-16A20 and NP16-A30 are featured with AC current monitoring function. However, local current reading display and temperature sensing port are not equipped.

TS-0300 is an Environment Temperature Sensor Probe. It is an optional part for NP-1601D.

Applications:
  • Controlling user equipment that requires operation AC power range from 100 VAC to 230 VAC, 50 to 60 Hz
  • Control power sources for your equipment with your cellular phone or via emails when you are on the road or stuck in traffic.
  • Scheduling AC outlet power cycling periodically or weekly scheduling.
Highlights
  • 16 Independently Managed Power Outlets
  • Redundant internal Power Supplies for More Reliable Operation
  • AC Current Draw Monitoring (optional feature)
  • Source IP Address Access Filtering/Blocking
  • Telnet
  • Web Browsing
  • Email Interacting
  • SNMP/Trap
  • AutoPing & Reboot. Event Reporting via Emails.
  • Modem Interface
  • Local Control
  • Manual Outlet Power Control Switch
  • Standalone Calendar/Clock Timer for Each Power Outlet's Control
Features
  • Standard 19” 2U chassis. 6” in depth.
  • Handles large current equipment up to 30A @110VAC - 20A @220 VAC.
  • 16 independently managed power outlets. Each power outlet is user name and password protected.
  • Current Draw Monitoring (Optional) for user to view AC current draw from all power outlets. It includes settings for user defined alarm threshold, alarm methods (Emails, TRAP, data log) and alarm message sending intervals.
  • 2 redundant internal power supplies for more reliable operation.
  • One DB-9F(DCE) RS232 service port and one RJ45 Ethernet port.
  • Source IP address Access Filtering/Blocking. Only one IP or a group of IP addresses can access the system.
  • AutoPing and power reboot for each power outlet.
  • Event timers for each power outlet so that an outlet is capable of executing recycling power with desired calendar date, real-time clock, and period and duty cycle.
  • Telnet accessibility. Menu driven or command-in-line configuration setup.
  • Embedded Web server enables user to easily change settings, view or alter system status.
  • Integrated SNMP agent and Trap notification capability.
  • POP3/SMTP for sending and receiving emails. Via Emails, users are able to send commands, such as power reboot.
  • Dial-up modem connection via local serial port.
  • Administration and User level name and password protection, including user name and password authentication for Web access or email sending.
  • Calendar/Real-time clock timer for each power outlet's power control.
Specifications

Item NP-16 NP-1601D NP-1601DH NP-16A20 NP-16A30
Power Input: 30 Amps Max 30 Amps Max 20 Amps Max 20 Amps Max 30 Amps Max
Voltage Range 110VAC
(Also support 220V)
110VAC
(Also support 220V)
220VAC 110VAC
(Also support 220V)
110VAC
(Also support 220V)
Power Input Cord Two Power Cords Two Power Cords Two IEC-320 C14s One Power Cord One Power Cord
AC Output Outlets 16 16 16 16 16
Outlet Type NEMA 5-15 NEMA 5-15 IEC-320 C13 NEMA 5-15 NEMA 5-15
Total Load (Combine all AC outlets) 15+15 15+15 10+10 20 30
AC Current Monitoring NO YES YES Yes Yes
Temperature Sensing NO Yes. (Sensor sold separately) Yes. (Sensor sold separately) NO NO
Console Interface – Local Master Port 1 RS232 Port. RJ-45 Connector. Data: 7 or 8 bits. Stop Bits: 1 or 2. Parity: None, Odd or Even. Flow Control: None or RTS/CTS. Baud Rate: 2400 to 115200.
Network Interface 10-Base T. RJ-45.
LED 16 Power outlet On/Off status LEDs 2 Network LEDs. 16 Power outlet On/Off status LEDs 2 Network LEDs. 2 digits AC readling . 16 Power outlet On/Off status LEDs 2 Network LEDs. 2 digits AC readling. 16 Power outlet On/Off status LEDs 2 Network LEDs. 16 Power outlet On/Off status LEDs 2 Network LEDs.
Weight 9 9 8 10 10
Operational Temperature Environment -25C° – 50C°
Humidity 5-95%, non-condensing
Safety and EMI Compliance Yes. TUV(US), UL-60950, FCC Class A
Downloads
NP-16A30 Datasheet
NP-16A30 Startup Guide

NP-1601DH Datasheet
NP-1601DH Startup Guide

NP-16A30 Datasheet
NP-16A30 Startup Guide

NP-16A20 Datasheet
NP-16A20 Startup Guide

NP-1601D Datasheet
NP-1601D Startup Guide

NP netBooter Manual
Click here to view NP netBooter demo
Accessories
C-RJ45-DB9F-4: RS-232 Serial RJ-45 to DB9 Female (DCE) Conversion Cable.
C-RJ45-DB9M-4: RS-232 Serial RJ-45 to DB9 Male (DTE) Conversion Cable.
Copyright © 2003-2010 Synaccess Networks, Inc. All Rights Reserved.